Use a piecewise linear formula to calculate battery %
Diffstat (limited to 'src')
-rw-r--r--src/tangara/battery/battery.cpp37
1 files changed, 31 insertions, 6 deletions
diff --git a/src/tangara/battery/battery.cpp b/src/tangara/battery/battery.cpp
index 9bde86a8..f68746ae 100644
--- a/src/tangara/battery/battery.cpp
+++ b/src/tangara/battery/battery.cpp
@@ -26,6 +26,8 @@ static const TickType_t kBatteryCheckPeriod = pdMS_TO_TICKS(60 * 1000);
*/
static const uint32_t kFullChargeMilliVolts = 4200;
+static const uint32_t kCriticalChargeMilliVolts = 3500;
+
/*
* Battery voltage, in millivolts, at which *we* will consider the battery to
* be completely discharged. This is intentionally higher than the charger IC
@@ -65,12 +67,35 @@ auto Battery::Update() -> void {
// Ideally the way you're 'supposed' to measure battery charge percent is to
// keep continuous track of the amps going in and out of it at any point. I'm
// skeptical of this approach, and we're not set up with the hardware needed
- // to do it anyway. Instead, we use a curve-fitting formula by StackOverflow
- // user 'Roho' to estimate the remaining capacity based on the battery's
- // voltage. This seems to work pretty good!
- double v = mV / 1000.0;
- uint_fast8_t percent = static_cast<uint_fast8_t>(std::clamp<double>(
- 123 - (123 / std::pow(1 + std::pow(v / 3.7, 80.0), 0.165)), 0.0, 100.0));
+ // to do it anyway. Instead, we use a piecewise linear formula derived from
+ // voltage measurements of our actual cells.
+ uint_fast8_t percent;
+ if (mV > kCriticalChargeMilliVolts) {
+ // Above the 'critical' point, the relationship between battery voltage and
+ // charge percentage is close enough to linear.
+ percent = ((mV - kCriticalChargeMilliVolts) * 100 /
+ (kFullChargeMilliVolts - kCriticalChargeMilliVolts)) +
+ 5;
+ } else {
+ // Below the 'critical' point, battery voltage drops very very quickly.
+ // Give this part of the curve the lowest 5% to work with.
+ percent = (mV - kEmptyChargeMilliVolts) * 5 /
+ (kCriticalChargeMilliVolts - kEmptyChargeMilliVolts);
+ }
+
+ // A full charge is always 100%.
+ if (charge_state == ChargeStatus::kFullCharge) {
+ percent = 100;
+ }
+ // Critical charge is always <= 5%
+ if (charge_state == ChargeStatus::kBatteryCritical) {
+ percent = std::min<uint_fast8_t>(percent, 5);
+ }
+ // When very close to full, the BMS transitions to a constant-voltage charge
+ // algorithm. Hold off on reporting 100% charge until this stage is finished.
+ if (percent >= 95 && charge_state != ChargeStatus::kFullCharge) {
+ percent = std::min<uint_fast8_t>(percent, 95);
+ }
bool is_charging;